Software configuration settings
Below are the necessary settings for using the various software programs with Telesto. If you create a new account or replace your computer, please reconfigure the settings as outlined here.
MAESTRO4 SETTINGS
Settings - Common - Com & Device Selection...:
Telescope - COM3 - Legacy (checked)
NINA SETTINGS
Connections - Equipment
Camera:
QHY600MPCIE (f6928a7f) (these are the optical fibers)
Connect and then change the settings on the camera page:
Default gain - 56 (25 is the Unitary gain)
Default offset - 10
Readout mode for snapshots - High Gain Mode 16BIT
Readout mode for sequences - High Gain Mode 16BIT
Filter wheel:
ASCOM - QHYFWRS232 FilterWheel
Settings - QHYCFW Generation: QHYCFW2/3 & Comm Port: COM6
The filters order is the following:
- U
- B
- V
- R
- I
- SII
- OIII
- H-alpha
- L
Focuser:
ASCOM - Device Hub Focuser
Settings - Focuser Device - Choose - ASCOM FOcuser Driver for OSBus
Rotator:
No rotator
Mount:
ASCOM - Astrometric telescope control via Maestro
Settings - Telescope Device - Choose - Maestro by Astrometric Inst.
Guider:
No guider
Dome:
ASCOM - Device Hub Dome
Settings - Dome Device - Choose - Shelyak Dometracker ASCOM driver
Settings - Dome Device - Choose - Properties... - Insert the data below:
Options
General:
Name: Telesto
Sky Survey cache folder: E:\NINA_FramingAssistantCache
Equipment:
Telescope Name: Telesto
Focal length: 2280 mm
Focal ratio: 3.8
Mount name: Officina Stellare
Planetarium: Stellarium
Filter wheel: write the correct names of the filters
Dome:
Mount Type - Fork on Wedge
Dome radius - 3000 mm
Allow sync while mount slews - ON
Sync slew dome when scope slews - ON
Find home before parking - OFF
Imaging:
Image file path: E:\images_nina\
Plate Solving:
Plate solver - ASTAP
Blind solver - ASTAP
STELLARIUM SETTINGS
List COMS:
COM3 - Telescope, Maestro
COM4 - OSBus
COM5 - Dome
COM6 - Filter wheel
COM7 - Weather Station and Safety Monitor